0 EA
no
show
  
Àαâ°Ë»ö¾î > °èÃø±â  ÃøÁ¤±â  ½ÃÇè±âÅ×½ºÅÍ±â  °Ë»ç±â  ŽÁö±â 
»óÇ°¼ö : 0 °³ + ¹è¼Û·á : 0 ¿ø = ÇÕ°è : 0 ¿ø
   ÇöÀçÀ§Ä¡ : HOME > Àü±â ÀüÀÚ °èÃø±â  >  
°íÁ¤¹Ð LCR Meter (LCR-612R/+RS232C)
ÆǸŰ¡°Ý  : 387,200¿ø [VATÆ÷ÇÔ]
ºê·£µå  : TECPEL
Á¦Á¶»ç  : Taiwan
Á¦Ç°Äڵ堠: LCR 612
¹«ÀÌÀÚÇҺΠ :
¼Ò°³Çϱ⠠:
ÁÖ¹®¼ö·®  :
°³
lor=#ff0000>

nProvided up to 4 testing parameters:       

 Ls+(Q,D,Rs), Lp+(Q,D,Rp) ; Cs+(Q,D,Rs), Cp+(Q,D,Rp)

nAuto-Power Off function:                       

  To conserve battery life for longer use.

nFuse detection function:                                   

 To inform that the fuse is open or damaged.

nPC communication port: (Only for Model  LCR 612R ) 

 Provide  optical standard RS-232. cable

 nExternal DC Adapter functions:                         

 Use of a DC adapter can also serve to disable

 Auto Power Off function.

nThe test lead TL-06 (Option) is specially designed for measuring SMD  (Surfac

e m

Specifications:

Display:

LCR 4  digits, maximum reading of 19999.

QDR 4 digits, maximum reading of 9999. (Auto range).

Capacitance Ranges: 
 8 Ranges 1KHz   Accuracy 120Hz  Accuracy
 20 mF   Nil +/-(5.0 %+5 Counts)/(DF<0.1)
 2000 uF +/-(5.0 %+5counts)/(DF<0.1) +/-(1.0 %+5 counts)/(DF<0.1)
 200 uF +/-(1.0 %+5 counts)/(DF<0.5) +/-(0.7 %+3counts)/(DF<0.5)
 20 uF +/-(0.7 %+3 counts)/(DF<0.5) +/-(0.7 %+3 counts)/(DF<0.5)
 2000 nF +/-(0.7 %+3 counts)/(DF<0.5) +/-(0.7 %+3 counts)/(DF<0.5)
 200 nF +/-(0.7 %+3 counts)/(DF<0.5) +/-(0.7 %+5 counts)/(DF<0.5)
 20 nF +/-(0.7 %+5 counts)/(DF<0.5) +/-(1.0  %+5 counts)/(DF<0.1)
2000 pF +/-(1.0 %+5 counts)/(DF<0.1)  Nil

Resolution up to 0.1 pF 

Inductance Ranges:  (DF < 0.5)

8 Ranges  1KHz Accuracy  120Hz Accuracy
10000 H  Nil  No specified
2000 H  No specified  +/-(1.0%+5 counts)
200 H +/-(1.0%+5 counts) +/-(0.7% + 5 counts)
20 H +/-(0.7 %+5 counts)  =/-(0.7%+5 counts)
2000 mH +/-(0.7 %+5 counts)  +/-(0.7%+5 counts)
200 mH +/-(0.7 %+5 counts)  +/-(1.0%+5 counts)
20 mH +/-(1.2%+5 counts)  +/-(2.0%+5 counts)
2000 uH +/-(2.0%+5 counts)  Nil

Resolution up to 0.1uH

Resistance Ranges:

 7 Ranges   1KHz/ 120 Hz Accuracy
10 M Ohm  +/-( 2.0% +8 counts)
2000 K Ohm  +/- (0.5% + 5 counts)
200 K Ohm  +/- (0.5% + 3 counts )
20 K Ohm  +/- ( 0.5% + 3 counts)
2000 K Ohm  +/- ( 0.5% + 5 counts)
200 K Ohm  +/- ( 0.8% + 5 counts)
20 Ohm  +/- ( 1.2% + 8 counts)

Resolution  up to  0.001  Ohm

Parameter Measurement:

Ls+(Q,D,Rs), Lp+(Q,D,Rp); Cs+(Q,D,Rs), Cp+(Q,D,Rp)

Overload: "OL" is display.
Range Mode: .  Auto and Manual
Test Frequency:

1KHz and 120Hz.

Measurement rate:  Approx. 1 time per second, nominal.

General

Power Requirement:

(1) Single Standard 9V battery (NEDA 1604, IEC 6F22 006P)

(2). External DC Adapter 12Vmim to 15Vmax / 50mA. (Optional)

Auto Power Off:

The meter key switch inactive for more than 5 minutes,                           .

Overload Protection  0.1A/250V fast below fuse.
Ambient Operating Ranges  0 deg C to 50 deg C(-32 deg F to 122 deg F) < 80% R.H.
Sotragne Temperature -20 deg C to 60 deg C(-4 deg F to 140 deg F) < 70 % R.H.

Dimensions:

 192mm(H) x 91mm(W) x 52.5mm(D).

Weight:

 365g. (including accessories)

Accessories:

Comes complete with leads, battery and owners manual.

LCR Test Lead¡¡

ount device) resistor, capacitor and inductor

* ¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
»óÇ°Á¤º¸°í½Ã
Á¦Ç°¸í °íÁ¤¹Ð LCR Meter (LCR-612R/+RS232C)
ÆǸŰ¡°Ý 387,200¿ø
ºê·£µå TECPEL
Á¦Á¶»ç Taiwan
À§ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
 
¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥ ºñ°í
ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
  »óÇ°¹®ÀÇÇϱâ
±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
- ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
- ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
- ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

!! ÁÖÀÇ»çÇ×
ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
°áÁ¦ÈÄ 2~5ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ·Ôµ¥Åù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
30¸¸¿ø ÀÌ»ó ±¸ÀԽà "Åùè¹ß¼Û" Á¦Ç°¿¡ ÇÑÇؼ­ ¹«·á¹è¼ÛµË´Ï´Ù.
(Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)

Åùè¹ß¼Û èâ ¿ë´Þ,Äü,È­¹°ºñ¿ëÀº ±¸¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
(±Û·Îºê¹Ú½º,µ¥½Ã°ÔÀÌÅÍ µî Àåºñ·ù´Â ÅùèºÒ°¡ÇÕ´Ï´Ù.)
°áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.