0 EA
no
show
  
Àαâ°Ë»ö¾î > °èÃø±â  ÃøÁ¤±â  ½ÃÇè±âÅ×½ºÅÍ±â  °Ë»ç±â  ŽÁö±â 
»óÇ°¼ö : 0 °³ + ¹è¼Û·á : 0 ¿ø = ÇÕ°è : 0 ¿ø
   ÇöÀçÀ§Ä¡ : HOME > ÀÌÈ­ÇÐ/°úÇбâ/±¼Àý/Æí±¤ /ÈÖµµ /½ÇÇèÃÊÀÚ/¼¼¶ó¹Í  >  
Ç׿ ¼öÁ¶(11L)
ÆǸŰ¡°Ý  : °¡°Ý¹®ÀÇ [VATÆ÷ÇÔ]
ºê·£µå  : JSR
Á¦Á¶»ç  : korea
Á¦Ç°Äڵ堠: JSIB-11T
¹«ÀÌÀÚÇҺΠ :
¼Ò°³Çϱ⠠:
ÁÖ¹®¼ö·®  :
°³


 

Water bath control temperature range from ambient +5¡É to 99.9¡É, with internal and external circulation pump.

Internal circulation enables precise temperature uniformity in the bath within ¡¾ 0.1¡É Comparing to conventional heated water bath without circulation system

 

External circulation pump enables to circulates water (liquid) to external equipments which needs to be kept constant temperature.

External circulation flow rate is 12 liters/minute and pressure is 250 mbar.

Main Specifications


¢ºTemp. Range  : ambient +5
¡É ~99¡É             


¢º
Controller : Digital PID Control


¢º
Accuracy :
¡¾ 0.1¡É


¢º
Uniformity :
¡¾ 0.2¡É


¢º
Circulation : Internal and external up to 12 liters/min


¢º
Capacity : 11 / 22 Liters


Á¤¹Ð¿ÂµµÁ¦¾î

 

½ºÅ×Àη¹½º È÷ÅÍ¿Í ¿À¹öÇìµå ÆßÇÁ·Î ¼øȯµÇ¾î ¿Âµµ°¡ Á¤¹ÐÇÏ°í ºÐÆ÷µµ°¡ ¶Ù¾î³ª Á¤¹Ð ¿Âµµ Á¦¾î¸¦ ¿äÇÏ´Â ½ÇÇè¿¡ ÀûÇÕ

ÃÖ´ë 99 ¡É, ¡¾ 0.1¡ÉÀÇ Á¤¹Ðµµ¿Í ¡¾ 0.2¡ÉÀÇ ¿Âµµ ºÐÆ÷µµ

µðÁöÅÐ PID Á¦¾î ¹æ½ÄÀ¸·Î ¡¾ 0.1¡ÉÀ̳»ÀÇ ¿Âµµ Á¦¾î ´É·Â

°ú¿­ ¹æÁö ÀåÄ¡, ¾Ë¶÷, ŸÀ̸Ó, ¿ÀÅäÆ©´×, ¿Âµµ º¸Á¤ ±â´É


 

Æí¸®ÇÑ ¼øȯ±â´É


ÀÌÀ½»õ ¾ø´Â ½ºÅ×Àη¹½º ÀçÁúÀÇ ¹è½º´Â ¼¼Ã´ÀÌ °£Æí À¯Áöº¸¼ö°¡ Æí¸®

½ºÅ×Àη¹½º ÀçÁúÀÇ ÆßÇÁ ¾î¼Àºí¸®´Â ºÎ½Ä¿¡ °­ÇÔ.

¿À¹öÇìµå ¹æ½ÄÀÇ ÆßÇÁ´Â 12L/min, 250mbarÀÇ ¾Ð·Â

¼öÁ¶ ³»ºÎ¿Í ¿ÜºÎ·Î Ç׿¼ö¸¦ ¼øȯ



Specifications & Ordering Information

Cat.No Descript-xion Size
JSIB-11T Internal and External up to 12 liters/min 11L
JSIB-22T Internal and External up to 12 liters/min 22L

Model
JSIB-11T
JSIB-22T
Bath Capacity
11L
22L
Dimensions W*D*H mm
Inner
370*240*150
500*300*150
Outer
370*295*440
560*340*440
Usable
130*240*150
330*300*150
Tempperature
Range
ambient +5¡É ~ 99¡É
Accuracy
¡¾0.1 ¡É
Uniformity
¡¾0.2 ¡É
Material
Bath
Seamless Stainless Steel 304 Electro-Polished
Body
Steel with Epoxy Powder Coating
Circulation Pump
Internal and External / Capacity 12 liter/min/250mbar
Controller
Digital PID controller with Timer and Auto-Tuning
Display
4 Digit LED Dispaly
Sensor
Pt 100 §Ù
Safety
Over Temp. Cut-Out / Over Current Leakage Breaker
Electrical Requirement
220 VAC 50/60 Hz or 120 VAC60 Hz

* ¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
»óÇ°Á¤º¸°í½Ã
Á¦Ç°¸í Ç׿ ¼öÁ¶(11L)
ÆǸŰ¡°Ý °¡°Ý¹®ÀÇ
ºê·£µå JSR
Á¦Á¶»ç korea
À§ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
 
¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥ ºñ°í
ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
  »óÇ°¹®ÀÇÇϱâ
±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
- ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
- ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
- ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

!! ÁÖÀÇ»çÇ×
ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
°áÁ¦ÈÄ 2~5ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ·Ôµ¥Åù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
30¸¸¿ø ÀÌ»ó ±¸ÀԽà "Åùè¹ß¼Û" Á¦Ç°¿¡ ÇÑÇؼ­ ¹«·á¹è¼ÛµË´Ï´Ù.
(Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)

Åùè¹ß¼Û èâ ¿ë´Þ,Äü,È­¹°ºñ¿ëÀº ±¸¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
(±Û·Îºê¹Ú½º,µ¥½Ã°ÔÀÌÅÍ µî Àåºñ·ù´Â ÅùèºÒ°¡ÇÕ´Ï´Ù.)
°áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
ȸ»ç : (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷| ´ëÇ¥ÀüÈ­ : 032-555-5645| Æѽº : 032-571-4445| glovebox-kr@naver.com
ÁÖ¼Ò : ÀÎõ±¤¿ª½Ã °è¾ç±¸ ÁÖºÎÅä·Î413¹ø±æ 32 1Ãþ (ÀÛÀüµ¿)| »ç¾÷ÀÚµî·Ï¹øÈ£ : 121-86-02196 [»ç¾÷ÀÚ¹øÈ£Á¶È¸]
´ëÇ¥ : ÇãÁ¾¼ø| Åë½ÅÆǸž÷½Å°í : Á¦2015-ÀÎõ°è¾ç-0634È£

COPYRIGHT (C) HY »ê¾÷ ALL RIGHT RESERVED.