0 EA
no
show
  
Àαâ°Ë»ö¾î > °èÃø±â  ÃøÁ¤±â  ½ÃÇè±âÅ×½ºÅÍ±â  °Ë»ç±â  ŽÁö±â 
»óÇ°¼ö : 0 °³ + ¹è¼Û·á : 0 ¿ø = ÇÕ°è : 0 ¿ø
   ÇöÀçÀ§Ä¡ : HOME > ÀÌÈ­ÇÐ/°úÇбâ/±¼Àý/Æí±¤ /ÈÖµµ /½ÇÇèÃÊÀÚ/¼¼¶ó¹Í  >  
VDL115 , °¡¿¬¼º ¿ë¸Å ¿ë ¾ÈÀü Áø°ø °ÇÁ¶ ¿Àºì, Safety vacuum drying oven for flammable solvents
ÆǸŰ¡°Ý  : °¡°Ý¹®ÀÇ [VATÆ÷ÇÔ]
ºê·£µå  : BINDER
Á¦Á¶»ç  : µ¶ÀÏ
Á¦Ç°Äڵ堠: VDL115
¹«ÀÌÀÚÇҺΠ :
¼Ò°³Çϱ⠠:
ÁÖ¹®¼ö·®  :
°³


Safety vacuum drying oven for flammable solvents
°¡¿¬¼º ¿ë¸Å ¿ë ¾ÈÀü Áø°ø °ÇÁ¶ ¿Àºì
 
³»ºÎ è¹ö´Â Zone II 3G¿¡ ´ëÇÑ ATEX Áöħ¿¡ µû¶ó ¼³°èµÇ¾ú½À´Ï´Ù.
¿Âµµ Á¤È®µµ¿Í ÀçÇö¼ºÀÖ´Â °á°ú¸¦ º¸ÀåÇÏ´Â 2 °³ÀÇ È®Àå ·¢ÀÌÀÖ´Â ÀüÀÚ Á¦¾îÇü APT.line ¢â ¿¹¿­ è¹ö
ÁÖÀ§ ¿Âµµº¸´Ù 15 ¡Æ C¿¡¼­ 200 ¡Æ C±îÁöÀÇ ¿Âµµ ¹üÀ§
MP ÄÁÆ®·Ñ·¯´Â 2 °³ÀÇ ÇÁ·Î±×·¥À¸·Î 10 °³ÀÇ ¼½¼ÇÀ¸·Î ±¸¼ºµÇ°Å³ª 1 °³ÀÇ ÇÁ·Î±×·¥À¸·Î 20 °³ÀÇ ¼½¼ÇÀ¸·Î Àüȯ °¡´É
¸®¾ó ŸÀÓ ±â´ÉÀ» °®Ãá ÅëÇÕ ÁÖ°£ ÇÁ·Î±×·¥ ŸÀ̸Ó
Á¤È®µµ 1 µµÀÇ µðÁöÅÐ ¿Âµµ ¼³Á¤
°æ°ú ½Ã°£ Ç¥½Ã±â
ºÐ¼â º¸È£ ±â´ÉÀÌÀÖ´Â ½ºÇÁ¸µ ÀåÂø ¾ÈÀü À¯¸® ÆгÎ
Á¤¹Ð Á¶Á¤½Ä ȯ±â ¹ëºê
±³Â÷ È帧 ±â¼úÀÌ Àû¿ëµÈ Á¤¹Ð Á¶Á¤ °¡´ÉÇÑ ºñÈ°¼º °¡½º ¹ëºê
¾ÈÀü ±â´É :
È°¼ºÈ­ µÈ <125 mbarÀÇ °¡¿­ ¿ë ¾Ð·Â Á¦¾î ÀåÄ¡
¾ÐÃà °ø±â ¿¬°á ¹× À¯Áö º¸¼ö ÀåÄ¡°¡ÀÖ´Â °ú¾Ð ĸ½¶È­ µÈ °è±âÆÇ
È­¿° ¹æÁö °³½ºÅ¶
¾Æ³¯·Î±× ¾Ð·Â °ÔÀÌÁö (³»ºÎ è¹ö¿Í ÁÖº¯ ¾Ð·Â »çÀÌÀÇ ¾Ð·Â Â÷¸¦ Ç¥½Ã)
Àü±â ¿¬¸¶ µÈ ³»ºÎ è¹ö, ÈíÀÔ ¹× ȯ±â Æ©ºê, ¾Ð·Â ¿ë±â, È®Àå ·¢ ¹× º¼ ¹ëºê´Â ½ºÅ×Àη¹½º °­À¸·Î ¸¸µé¾îÁý´Ï´Ù.
°­È­ ½Ç¸®ÄÜÀ¸·Î ¸¸µç µµ¾î °³½ºÅ¶
½Ã°¢Àû ¿Âµµ °æº¸ ±â´ÉÀÌÀÖ´Â µ¶¸³Çü ¿Âµµ Á¶Àý ÀåÄ¡ Ŭ·¡½º 2 (DIN 12880)
Èĸé ÆгÎÀÇ ÃøÁ¤ Æ÷Æ® DN 16
¿É¼Ç GMP / GLP ¹× FDA °¡ÀÌµå ¶óÀΰú ÇÔ²² »ç¿ëÇϱâÀ§ÇÑ RS 422 ÀÎÅÍÆäÀ̽º 21 CFR Part 11 ȣȯ APT-COM ¢â DataControlSystem ¼ÒÇÁÆ®¿þ¾î
ƯÇã¹ÞÀº 2 °³ÀÇ À¯¿¬ÇÑ ¾Ë·ç¹Ì´½ È®Àå ·¢
¸ðµç Àü±â ±¸¼º ¿ä¼Ò´Â ³»ºÎ è¹ö¿¡¼­ ºÐ¸®µË´Ï´Ù.
¸ðµâ ¹× Áø°ø ÆßÇÁ¿Í ÇÔ²² ¿Ïº®ÇÑ ½Ã½ºÅÛÀ¸·Î »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. dz¸ð:
¡å ¼ÒÀ½ ¼öÁØ °¨¼Ò

¡å ½Ç¿ëÀûÀÎ ÀÛ¾÷ ³ôÀÌ

¡å ±ÕÇü ÀâÈù ½Ã½ºÅÛ

BINDER Å×½ºÆ® È®ÀÎ
 

Cat No.

Description

Model

Volume

Option

 

 

 

 

 

9030-0040

VDL series | Vacuum drying ovens for flammable solvents

VDL 115

115 l

Standard equipment

 

 

Inner chamber is designed according to ATEX guidelines for Zone II 3G
Electronically controlled APT.line¢â preheating chamber with 2 expansion racks assuring temperature accuracy and reproducible results
Temperature range from 15 ¡ÆC above ambient temperature to 200 ¡ÆC
MP controller with 2 programs with 10 sections each or switchable to 1 program with 20 sections
Integrated weekly program timer with real-time function
Digital temperature setting with an accuracy of one degree
Elapsed time indicator
Spring-mounted safety glass panel with shatter protection
Precision-adjustable ventilation valve
Precision-adjustable inert gas valve with Cross-Flow-Technology
Safety features:
Pressure control device for heating activated < 125 mbar
Over pressure capsuled instrument panel with compressed air connection and maintenance unit
Flame protection gasket
Analog pressure gauge (displays pressure difference between the inner chamber and ambient pressure)
Electro polished inner chamber, suction and ventilation tubes, pressure container, expansion racks, and ball valve are made of stainless steel
Door gasket made of tempered silicone
Independent adjustable temperature safety device class 2 (DIN 12880), with visual temperature alarm
Measuring port DN 16 in rear panel
RS 422 interface for use with optional GMP/GLP and FDA guideline 21 CFR Part 11 compliant APT-COM¢â DataControlSystem software
2 patented, flexible aluminum expansion racks
All electrical components are decoupled from the inner chamber
Available as a complete system, with module and vacuum pump. Features:
     ¡å Reduced sound level

     ¡å Practical working height

     ¡å Well balanced system

BINDER test confirmation

»ç¾ç   VDL 115  

 

Width (mm)

740

Height (incl. feet) (mm)

900

Height with optional vacuum module (mm)

625

Total Height with optional vacuum module (mm)

1525

Depth (mm)

670

Plus door handle, connection (mm)

100

Wall clearance, rear (mm)

100

Wall clearance, side (mm)

135

 

 

Interior dimensions

 

Width (mm)

506

Height (mm)

506

Depth (mm)

460

Interior volume (l)

* ¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
»óÇ°Á¤º¸°í½Ã
Á¦Ç°¸í VDL115 , °¡¿¬¼º ¿ë¸Å ¿ë ¾ÈÀü Áø°ø °ÇÁ¶ ¿Àºì, Safety vacuum drying oven for flammable solvents
ÆǸŰ¡°Ý °¡°Ý¹®ÀÇ
ºê·£µå BINDER
Á¦Á¶»ç µ¶ÀÏ
À§ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
 
¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥ ºñ°í
ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
  »óÇ°¹®ÀÇÇϱâ
±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
- ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
- ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
- ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

!! ÁÖÀÇ»çÇ×
ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
°áÁ¦ÈÄ 2~5ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ·Ôµ¥Åù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
30¸¸¿ø ÀÌ»ó ±¸ÀԽà "Åùè¹ß¼Û" Á¦Ç°¿¡ ÇÑÇؼ­ ¹«·á¹è¼ÛµË´Ï´Ù.
(Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)

Åùè¹ß¼Û èâ ¿ë´Þ,Äü,È­¹°ºñ¿ëÀº ±¸¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
(±Û·Îºê¹Ú½º,µ¥½Ã°ÔÀÌÅÍ µî Àåºñ·ù´Â ÅùèºÒ°¡ÇÕ´Ï´Ù.)
°áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
ȸ»ç : (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷| ´ëÇ¥ÀüÈ­ : 032-555-5645| Æѽº : 032-571-4445| glovebox-kr@naver.com
ÁÖ¼Ò : ÀÎõ±¤¿ª½Ã °è¾ç±¸ ÁÖºÎÅä·Î413¹ø±æ 32 1Ãþ (ÀÛÀüµ¿)| »ç¾÷ÀÚµî·Ï¹øÈ£ : 121-86-02196 [»ç¾÷ÀÚ¹øÈ£Á¶È¸]
´ëÇ¥ : ÇãÁ¾¼ø| Åë½ÅÆǸž÷½Å°í : Á¦2015-ÀÎõ°è¾ç-0634È£

COPYRIGHT (C) HY »ê¾÷ ALL RIGHT RESERVED.