Agriculture or biotechnology experiment of plant growth in an artificial climatic condition
Controls Temperature,
Relative Humidity and
Light intensity illumination
Main Specifications
¢ºTemp. Range : +5¡É ~ 60¡É
¢ºHumidity : 30 ~ 98% RH
¢ºIllumination : 0 ~ 25,000 Lux ( 40,000 Lux ) from Top
Illumination by FL & Metal Halide lamp
¢ºController-Basic PG-4CP Program Control
¢ºOption-Premium PG-300CP
Remote Control System
¢ºAccuracy : ¡¾ 0.1¡É
¢ºUniformity : ¡¾ 0.8¡É
¢ºHeating Type : Forced Convection
¢ºCapacity : 478 / 972 / 1512 Liters
ÇÁ·Î±×·¥ ¸¶ÀÌÅ©·Î ÇÁ·Î¼¼¼ Á¦¾î
ÅëÇÕÇü ¸¶ÀÌÅ©·ÎÇÁ·Î¼¼¼ Á¦¾îÀåÄ¡´Â ¿Âµµ, ½Àµµ, Á¶µµ, ¾ÈÀü ÀåÄ¡¸¦ µ¿½Ã¿¡ ¼Õ½±°Ô Á¦¾îÇÒ ¼ö ÀÖÀ¸¸ç »ç¿ëÀÚ ÀÎÅÍÆäÀ̽º°¡ ¸Å¿ì °£´ÜÇÏ¿© ÇÁ·Î±×·¥ Á¶ÀÛÀÌ °£ÆíÇÔ.
PG-300CPÇü ¸®¸ðÆ® ÄÜÆ®·Ñ ½Ã½ºÅÛ ¶Ç´Â PG-4CPÇü ÇÁ·Î±×·¥ ÄÜÆ®·Ñ·¯ ¼±ÅÃ
¿ì¼öÇÑ Á¦¾î ¼º´É
¿Âµµ¹üÀ§ 0 ~ 60¡É, ¡¾ 0.1¡ÉÀÇ Á¤¹Ðµµ
½Àµµ¹üÀ§ 30 ~ 98% RH, ¡¾ 3.0%ÀÇ Á¤¹Ðµµ
õÀå Á¶¸í ¶óÀÌÆ® ¹ðÅ© ¹æ½Ä
õÀå¿¡¼ Çü±¤µî°ú ¸ÞÅ»·¥ÇÁ ¶óÀÌÆ® ¹ðÅ© ½Ã½ºÅÛÀ» »ç¿ëÇÏ¿© ³ôÀº Á¶µµ¿Í è¹ö ³»ºÎ¿¡ °ñ°í·ç ºûÀ» ºÐ»ê
0 ~ 20,000 ·è½º (¿É¼Ç : 40,000 ·è½º)±îÁö Á¦¾î ÇÏ¸ç ¸ðµ¨¿¡ µû¶ó Á¶µµ¸¦ 6 ~ 8 ´Ü°è·Î Á¦¾î
·¥ÇÁ´Â ¼øÂ÷ÀûÀ¸·Î 1ºÐ °£°ÝÀ¸·Î Á¡µîµÇ¾î ±Þ°ÝÇÑ Á¶µµ º¯È·Î ÀÎÇÑ ½Ä¹° ½ºÆ®·¹½º ¹æÁö
¾ÈÀüÀåÄ¡ ÆíÀǼº
°ú¿ ¹æÁö ÀåÄ¡, ¾Ë¶÷, ŸÀ̸Ó, ¿ÀÅäÆ©´×, ¿Âµµº¸Á¤±â´É
Àú¼öÀ§ ¾Ë¶÷ ½Ã±×³Î°ú È÷ÅÍ °ú¿ ¹æÁö ÀåÄ¡
ÄÜÆ®·Ñ·¯ ÀÚü ÀÌ»ó Áø´Ü ±â´É
Specifications & Ordering Information
Cat.No |
Descript-xion |
Size |
JSGC-960C |
Top Illumination Light Bank System |
972L |
JSGC-1500C |
Top Illumination Light Bank System |
1512L |
JSGC-420C |
Top Illumination Light Bank System |
423L |
Model |
JSGC-420C |
JSGC-960C |
JSGC-1500C |
Chamber Volume (Capacity) |
423L |
972L |
1512L |
Temp.
|
Heating Type |
Forced Convection by silent coaxial fan |
Range |
+0¡É ~ 60¡É (without illumination) |
Accuracy |
¡¾0.1 ¡É at 20¡É |
Uniformity |
¡¾0.8 ¡É at 20¡É |
Humidity
|
Humidifier Type |
Water boiler with immersed incolony sheath heater |
Range |
30 % ~ 98 % RH(Altitude less than 2,000m) |
Accuracy |
¡¾3.0 % at 60% |
Uniformity |
¡¾6.0 % at 60% |
Illumination
|
Illumination Type |
Fluorescent Lamp & Metal Halide Lamp from the Top Light Bank |
Range |
0 ~ 20,000Lux (40,000Lux Optional) |
Control Step |
6 Steps |
8 Steps |
Feature |
Lamp-On-Delay Fuction by 1 minute of interval |
Control
|
Main Controller |
Digital Programmable Microprocessor PID Controller |
Program |
11 Segment, 999Cycle or continuous |
Sensor |
Pt 100 §Ù for Temperature Protection / Low Water Level Warning and Cut-Off |
Safety Device
|
Temp. |
Hydraulic Over Temperature Protection Safety Device |
Electrical |
Electrical Leakage Breaker |
Dimensions |
Inner |
600X600X1200 |
900X900X1200 |
1400X900X1200 |
WxDXH mm |
Outer |
1250X1100X2200 |
1560X1100X2200 |
2060X1100X2200 |
Material
|
Chamber |
1.0 Gauge Stainless Steel Polished (SUS304) |
External |
Steel 1T with Epoxy Powder Coating |
Door |
External Door with Magnetic Packing / Small viewing window |
Utility |
Water Inlet / Water Outlet / Over Flow / Drain |
Electrical Requirement |
120 VAC 60 Hz or 220 VAC 50/60 Hz | |
* ¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
»óÇ°Á¤º¸°í½Ã
Á¦Ç°¸í |
½Ä¹° »ýÀå»ó (423 Liters) |
ÆǸŰ¡°Ý |
°¡°Ý¹®ÀÇ |
ºê·£µå |
JSR |
Á¦Á¶»ç |
korea |
°áÁ¦ÈÄ 2~5ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ·Ôµ¥Åù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
30¸¸¿ø ÀÌ»ó ±¸ÀԽà "Åùè¹ß¼Û" Á¦Ç°¿¡ ÇÑÇؼ ¹«·á¹è¼ÛµË´Ï´Ù.