Turbidity Meter
AQ45000.01~2000NTU µÎ°³ÀÇ LED±¤¿ø»ç¿ë (White light LED,Infra-red LED) 100°³ µ¥ÀÌÅÍ ÀúÀÚ ¾ç¹æÇâ RS232 Åë½Å
Ư¡0.01~2000NTU µÎ°³ÀÇ LED±¤¿ø»ç¿ë (White light LED,Infra-red LED) 100°³ µ¥ÀÌÅÍ ÀúÀÚ ¾ç¹æÇâ RS232 Åë½Å±â´ÉµÎ °³ÀÇ LED ±¤¿øÀ» »ç¿ëÇÑ Å¹µµ°è - White light LED : US EPA 180.1 ÃøÁ¤¹ý - Infra-red LED : ISO/DIN ÃøÁ¤¹ý 100°³ µ¥ÀÌÅÍ ÀúÀå ¾ç¹æÇâ RS232 Åë½Å(ÄÉÀ̺í¿É¼Ç) ÃøÁ¤¸ðµå : EPA 180.1, ISO Nephelometric, ISO Absorbance, IR Ratiometric, 100% White, 100% IR, EBC, ASBC ÀÇ 8°¡Áö ¸ðµå ÃøÁ¤´ÜÀ§ : NTU, FTU, FNU, ASBC, EBC
¸ðµ¨¸í
AQ4500
ÃøÁ¤¹æ¹ý
EPA 180.1
0 to 2000NTU
EPA GLI Method 2
0 to 40NTU
ISO-NEPH(7027)
0 to 150FNU
ISO-ABSB
40 to 4000FAU
IR-RATIO
0 to 4000NTU
EBC
0 to 24.5EBC
ASBC
0 to 236ASBC
WHITE %T
0 to 100% T
IR %T
0 to 100%T
±¤¿ø
Light emitting diode(LED)
°ËÃâ
Silicon Photodiode
ÆÄÀå¼±ÅÃ
Automatic
ºÐÇØ´É
0.01NTU(0 to 9.99)
0.1NTU(10 to 99.9)
1NTU(100 to 1000)
Á¤È®µµ
¡¾ 2% of reading plus 0.01 NTU
(0 to 500 NTU)
¡¾ 3% of reading (500 to 1000 NTU)
¡¾ 5% of reading (1000 to 2000 NTU)
¹Ýº¹¼º(Repeatability)
¡¾ 1% of reading or 0.01 NTU
»ùÇÃÅ©±â
Approximately 12 mL
Operating Temperature
-40.0~60.0¡É
½Àµµ
90% relative humidity at 30.0¡É max
º¸È£µî±Þ
IP67
Å°Æеå
12 dual function keys with tactile
feedback
RS232
YES
»ùÇÃè¹ö
24mm
µð½ºÇ÷¹ÀÌ
Custom LCD
´ÜÀ§
FNU, NTU, FAU, ASBC, EBC
µ¥ÀÌÅͷαë
100points
Built-in Clock with Time
and Date Display
Yes
Auto Shut-off
Àü¿ø
4 AA batteries
¹èÅ͸®¼ö¸í
2,500 hours (alkaline) 10,000 hours
(lithium)
Non-volatile Memory
******************************************************************
AQ30100.01~1000NTU Ç¥Áؽþà: 0.02,20.0,100,800NTU IP67, CEÀÎÁõ ÀÚ°¡Áø´Ü
Ư¡0.01~1000NTU Ç¥Áؽþà: 0.02,20.0,100,800NTU IP67, CEÀÎÁõ ÀÚ°¡Áø´ÜÀû¿ëºÐ¾ß»óÇϼö, °ø¾÷¿ë¼ö, ½ÇÇè¿ë¼ö µîÀÇ Å¹µµÀÇ ÃøÁ¤ ±â´ÉISO 7027 ±Ô°Ý¿¡ ºÎÇÕÇϸç,Çâ»óµÈ Á¤È®µµ¸¦ À§ÇÑ ¾ÈÁ¤ÀûÀÎ ±¤¿ø EPA ½ÂÀÎµÈ Ç¥ÁØ¿ë¾×À» ÀÌ¿ëÇÏ¿© È¥ÇÕÀ̳ª Èñ¼® µîÀÇ ÀýÂ÷ ÇÊ¿ä ¾øÀ½ IP67 ¹æÁø,¹æ¼ö µî±Þ
LCD
ÃøÁ¤¹üÀ§
/ºÐÇØ´É
0.01 to 19.99 NTU with 0.01 NTU resolution
20.0 to 99.9 NTU with 0.1 NTU resolution
100 to 1000 NTU with 1 NTU resolution
Á¤¹Ðµµ
+/- 2% of reading +/- 1 LSD for 0-500 NTU
+/- 3% of reading +/- 1 LSD for 501-1000 NTU
ÀÀ´ä¼Óµµ
< 6 seconds
»ùÇ÷®
10 mL
Ç¥Áؽþà
0.02, 20.0, 100, and 800 NTU
»ùÇÃVials
25 mm diameter with indexing mark
IR LED for ISO 7027 turbidity measurement
ÁÖº¯µ¿Àۿµµ
0 to 50 C (0 to 90% non-condensing relative humidity at 30 C)
ÀÚ°¡Áø´Ü
Yes, with troubleshooting error codes
¹æ¼öµî±Þ
Regulatory Approvals
CE, TUV 3-in-1 for CSA-US, FCC part 15
4 x AAA > 3000 tests and (4 x AAA Lithium > 12000 tests)